INVT INVERTER GD 20
Dengan spesifikasi sebagai berikut :
Features :
Mini design, smaller installation space
Compatible with rail and wall installation, flexible installation manner
Available multi-inverter in parallel installation, more effective space-saving.
Applications :
- Packing
- Food
- Textile
- Centrifugal machinery
- Carving machinery
- And wire cutting
Made in : China
Function Description :
Power Input :
Rated Input Voltage (V) :
- 1PH 220V (-15%) – 240V (+10%)
- 1PH 220V (-15%) – 240V (+10%)
- 1PH 220V (-15%) – 240V (+10%)
Rated Input Current (A) : Refer to “Rated Value”
Rated Frequency (Hz) : 50Hz or 60 Hz, Permissible Range : 47~63 Hz
Power Output :
Rated Motor Capacity (Kw) : Refer to “Rated Value”
Rated Output (Kva) : Refer to “Rated Value”
Rated Current (A) : Refer to “Rated Value”
Rated Output Voltage (V) : Equal to Input Voltage with Less Than 5% Error
Technical Control performance:
Control Mode : SVPWM, SVC
Motor type : ASYNCHRONOUS MOTOR
Speed Range : 1:100
Speed Control Precision : ±0.2% (SVC)
Speed Fluctuation : ±0.3% (SVC)
Torque Response : <20MS (SVC)
Overload Capacity : 1M FOR 150% OF RATED CURRENT, 10S FOR 180% OF RATED CURRENT, 1S FOR 200% OF RATED CURRENT150%
RUNNING CONTROL CHARACTERISTICS :
FREQUENCY SETUP MODE :
- KEYPAD DIGITS, ANALOG QUANTITY, PULSE FREQUENCY, MULTI-STEP SPEED OPERATION, SIMPLE PLC, PID, MODBUS COMMUNICATION. REALIZE SWITCHING BETWEEN THE SET COMBINATION AND THE SET CHANNEL.
- REALIZE SWITCHING BETWEEN THE SET COMBINATION AND THE SET CHANNEL.
AUTO VOLTAGE ADJUSTMENT : KEEP THE OUTPUT VOLTAGE CONSTANT WHEN GRID VOLTAGE CHANGES.
FAULT PROTECTION : PROVIDE ALL-AROUND FAULT PROTECTION: OVERCURRENT, OVERVOLTAGE, UNDERVOLTAGE, OVERHEAT, PHASE LOSS AND OVERLOAD
SPEED TRACKING RESTART : REALIZE IMPACT-FREE SMOOTH STARTUP OF ROTATING MOTOR
AI : ONE (AI2) 0~10V/0~20MA, ONE (AI3) -10~10V
AO : TWO (AO1, AO2) 0~10V /0~20MA
DI :
- FOUR NORMAL INPUTS, MAX FREQUENCY: 1KHZ
- ONE HIGH SPEED INPUT, MAX FREQUENCY 50KHZ
DO : ONE Y1 TERMINAL OUTPUT, TWO PROGRAMMABLE RELAY OUTPUTS
RELAY OUTPUT :
- TWO PROGRAMMABLE RELAY OUTPUTS
- RO1A NO, RO1B NC, RO1C COMMON PORT
- RO2A NO, RO2B NC, RO2C COMMON PORT
- CONTACT CAPACITY:3A/AC250V
OTHERS :
DC REACTOR : 18.5KW AND ABOVE MODELS CARRY BUILT-IN DC REACTOR IN STANDARD CONFIGURATION
INSTALLATION MODE :
- 1PH 220V/3PH 380V AND BELOW AND 3PH 220V 0.75KW AND BELOW SUPPORT RAIL-TYPE AND WALL-TYPE INSTALLATION;
- 3PH 380V 4KW AND ABOVE AND 3PH 220V 1.5KW AND ABOVE SUPPORT WALL-TYPE AND FLANGE-TYPE INSTALLATION;
BRAKE UNIT : BUILT-IN IN STANDARD CONFIGURATION FOR 37KW AND BELOW MODELS AND OPTIONAL FOR 45~110KW MODELS;
EMC FILTER :
- BUILT-IN C3 FILTER IS OPTIONAL FOR 3PH 380V 4KW AND ABOVE, 3PH 220V 1.5KW AND ABOVE
- OPTIONAL FILTER: IEC61800-3 C2, IEC61800-3 C3
AMBIENT TEMP : 10~50 celcius, DERATE IF THE AMBIENT TEMP IS ABOVE 40 celcius
ELEVATION : BELOW 1000M, DERATE IF THE ELEVATION IS ABOVE 1000M, DERATE BY 1% PER EVERY ADDITIONAL 100M
PROTECTION LEVEL :
- IP20
- NOTE: THE INVERTER WITH PLASTIC SHELL SHOULD BE INSTALLED IN THE METAL DITRIBUTION BOX WHICH COMPLIES WITH IP20 AND IP3X
SAFETY : MEET CE REQUIREMENT
COOLING MODE : AIR COOLING
Ulasan